Acti 9 xID residual circuit breaker – 40 A – 4P – 30mA class AC instantaneous

+ Free Shipping

Product overview

  • Effective protection against electrocution due to direct and indirect contact and earth leakages
  • Easy monitoring with earth fault indication on front face
  • Field fittable auxiliaries available for monitoring and remote tripping
  • No accidental contact with live parts, thanks to finger-proof IP 20 terminals
  • Optimal safety at the system level with conditional short-circuit current 10kA

Product Description

This product is a Acti9 xID biconnect residual current circuit breaker (RCCB). It is a 4P circuit breaker with 40A In rated current, 30mA earth leakage sensitivity and AC type protection class. This product protects against electrical shock by direct or indirect contact and fire hazards. The connection is made downstream by biconnect comb busbar or upstream/downstream by tunnel terminals. It is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is up to 500A

Product Specification 

Range Acti9
Product name Acti9 xID
Product or component type Residual current circuit breaker (RCCB)
Device short name xID
Poles description 4P
Neutral position Left
[In] rated current 40 A
Network type AC
Earth-leakage sensitivity 30 mA
earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type AC
Rated breaking and making capacity 500 A conforming to EN/IEC 61008-1
Suitability for isolation Yes
Complementary
Network frequency 50 Hz
[Ue] rated operational voltage 400…415 V AC 50 Hz
[Ui] rated insulation voltage 500 V AC 50 Hz
[Uimp] rated impulse withstand voltage 6 kV
Contact position indicator Yes
control type Toggle
local signalling ON, OFF, fault trip
Mounting mode Clip-on
mounting support DIN rail
Comb busbar and distribution block compatibility Downside: biconnect
Connection pitch 18 mm between phases
9 mm pitches 8
height 81 mm
Width 72 mm
Depth 75 mm
Net weight 370 g
Colour White
Mechanical durability 4000 cycles
Electrical durability 4000 cycles
Locking options description Padlocking device
Connections – terminals Tunnel type terminals (top or bottom) 1…35 mm² rigid
Tunnel type terminals (top or bottom) 1…25 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 3.5 N.m top or bottom
Environment
Standards EN 61008-2-1
IEC 61008-2-1
EN/IEC 61008-1
product certifications ISI
IP degree of protection IP20
Pollution degree 2